Calog Calibrators Home
Calog Calibrator Products Contact Calog Calibrators Calog Calibrator News Calog Calibrator Distributors

CALOG Calibrators - Thermocouple Calibrator

Calog Thermocouple Calibrator

The CALOG Calibrators Thermocouple Calibrator is ideal for testing, measuring and calibration of all thermocouple based systems. In addition it contains functions to install and maintain all powered and non-powered milliamp loops.

The CALOG Calibrators - Thermocouple Calibrator is a high precision, multi-functional, hand-held calibrator suitable for the process control industry. Its speciality is thermocouple based instruments which it can measure and source. DC voltage, millivolts, milliamps and circuit continuity can also be measured. The trend feature is ideal for graphing temperature profiles and PID controller optimization. Its small size, long battery life and high precision make the CALOG Calibrators - Thermocouple Calibrator ideal for industrial field or workshop calibration.

Display Examples of the CALOG Calibrators Thermocouple Calibrator

Calog Thermocouple Calibrator Screen Calog Thermocouple Calibrator Screen2

Calog Thermocouple Calibrator buttons

Features of the CALOG Calibrators Thermocouple Calibrator

  • Measure, source and simulate 0 to 24 mA with 0.01% accuracy and 1 mA resolution
  • Measure 0 to 32V with 0.005% accuracy and 1mV resolution
  • Continuity test function
  • Increment, step, ramp or valve stroking
  • Trend logging with programmable timebase
  • Displays values in mA and % or % and mA
  • Built-in 24V power supply for mA loops
  • Measure and source types J, K, T, E, R, S, B, and N thermocouples with configurable internal or manual cold-junction compensation in either °C, °F, Kelvin or Rankine
  • Accuracy better than 0.5°C excluding cold junction errors and thermocouple errors
  • Measures and sources -10 to 100 mV with 0.01% accuracy and 1 mV resolution
  • Simultaneously source a thermocouple and measure mA
  • 2 year guarantee (batteries not included)
  • Carry case, charger and test leads supplied as standard

Technical Specifications of the CALOG Calibrators Thermocouple Calibrator

Analogue Input Ranges Impendance Accuracy Resolution
0 to24 mA Input Impedance ± 1Ώ, 250mA Fused 0.01% 1µA
0 to 32 V Input Impedance ±110 k Ώ 0.005% 1mV
-10 to 100 mV Input Impedance > 1M Ώ 0.01% 1µA
Continuity with 100 Ώ trigger and 1mA excitation. Gives visual and audible confirmation.
Analogue Output Ranges Load Accuracy Resolution
Types J, K, T, E, R, S, B and N thermocouples 0.05% 0.1°C
0 to 24 mA Output load max 500 Ώ 0.01% 1µA
-10 to 100 mV Output load min 600 Ώ 0.01% 1µV

Download Calog Thermocouple Calibrator Download Calog Thermocouple Calibrator Datasheet

* Full operating manuals, carry case, test leads and charger are supplied as standard.

 

Calog Thermocouple Calibrator
copyright © 2006 Calog Calibrators