 Calog Process Calibrator

The CALOG Calibrators - Pro is ideal for testing, installing and calibration of most process control systems, especially PLC based systems. It's main function is as a precision calibrator and measuring device of Voltage, Current and Frequency.

TheTREND feature is very useful for graphing profiles. This important feature can be used for recording, fault finding or optimizing control settings.

Extremely versatile, this unit can measure, source, and simultaneously measure and source, V, mA, mV (analog signals) along with frequency, pulses and counts (digital signals).

It also tests for continuity.

Calog Process Calibrator Screen Calog Process Calibrator Screen2

Calog Process Calibrator buttons

Features of the CALOG Calibrators - Process Calibrator

  • Measure, source or simulate 0 to 24 mA
  • Measure 0 to 32 Vdc and Source 0 to 12 Vdc
  • Measure and source -10 to 100 mV
  • Continuity test function
  • Measure and source frequency from 0 to 20kHz
  • Measure and source counts up to 8 digits (99 999 999)
  • Increment, step, auto step or ramp with built-in 24V power supply for mA loops
  • Displays values in mA and % or % and mA
  • Simultaneously measure and source all mA, mV and V combinations (not isolated)
  • This unit covers most requirements of PLC and SCADA applications.
  • Carry case, protective rubber boot, rechargeable battery, charger and test leads supplied as standard
  • 2 year guarantee against faulty material or workmanship (batteries not included)

Technical Specifications of the CALOG Calibrators - Process Calibrator

Analogue Input Ranges Impedance Accuracy Resolution
0 to 24 mA Input Impedance ± 17 Ώ, 250mA Fused 0.01% FS ± 1 digit 1µA
0 to 32 V Input Impedance ±110 kΏ 0.005% FS ± 1 digit 1mV
-10 to 100 mV Input Impedance >1 MΏ 0.005% FS ± 1 digit 1µV
0.00 to 100.00 Hz, trigger level up to 12.0 V Input Impedance 110 kΏ 0.01% FS ± 1 digit 0.01Hz
Pulses / min max = 6000.00 and Pulses / hour max = 360 000.00
0 to 20 000 Hz, trigger level up to 12.0 V Input Impedance 110 kΏ 0.01% FS ± 1 digit 1Hz
Pulses / Min max = 1 200 000 and Pulses / Hour max = 72 000 000
0 to 99 999 999 counts, trigger level up to 12.0 V in 0.1 V steps
Continuity with a <100 Ώ trigger using 1 V @ 1 mA. Gives visual and audible confirmation.
       
Analogue Output Ranges Maximum Load Accuracy Resolution
0 to 24 mA Output load max 500 Ώ 0.01% FS ± 1 digit 1µA
0 to 12 V Output load min 500 Ώ 0.01% FS ± 1 digit 1mV
-10 to 100 mV Output load min 100 Ώ 0.01% FS ± 1 digit 1µV
0.50 to 100.00 Hz, trigger level up to 12.0 V   0.01% FS ± 1 digit 0.01Hz
1 to 20 000 Hz, trigger level up to 12.0 V   0.01% FS ± 1 digit 1Hz
0 to 99 999 pulses, Baud rate up to 100, Amplitude up to 12.0 V      