- LOOP II Calibrator

The - LOOP II is the second generation of calibrator in the popular CALIBRATOR range. Using the latest ARM processor, the - LOOP II becomes a powerful field instrument, now with the added feature of datalogging.
The - LOOP II is a high precision, multi-function, hand-held calibrator designed for the process control industry. It’s speciality is milliamp loop powered instruments which it can measure, source and simulate. DC voltage and circuit continuity can also be measured.
The TREND logging feature is ideal for graphing and PID controller optimization. Datalogging stores data on the SD card supplied and is easily downloaded to a PC via the onboard USB port.
It's user friendly, compact size and high precision make the - LOOP II an ideal choice for industrial field or workshop calibration.
 
Features of the - LOOP II Calibrator
- Measure, source or simulate 0 to 24 mA
- Measure 0 to 32 Vdc
- Continuity test function
- Increment, step, auto step or ramp with built-in 24V power supply for mA loops
- Displays values in mA and % or % and mA
- Logged data is downloaded via the onboard USB port
- Trend logging with programmable timebase of all measured values
- Carry case, protective rubber boot, Li-ion battery, charger, test leads and SD card supplied as standard
- 2 year guarantee against faulty material or workmanship (batteries not included)
Technical Specifications of the - LOOP II Calibrator
| Analogue Input Ranges |
Impedance |
Accuracy |
Resolution |
| 0 to 24 mA |
Input Impedance ± 17 Ώ, 250mA Fused |
0.01%FS ±1 digit |
1µA |
| 0 to 32 V |
Input Impedance ± 110 k Ώ |
0.005%FS ±1 digit |
1mV |
| Continuity with a <100 Ώ trigger @ 1 mA. Gives visual and audible confirmation. |
| |
|
|
|
| Analogue Output Ranges |
Maximum Load |
Accuracy |
Resolution |
| 0 to 24 mA |
Output load max 500 Ώ |
0.01%FS ± 1 digit |
1µA |
Download Calog Loop II Datasheet
|